NFO Events (10703 / 20703)
The NFO Events module sends NFO's own operational events to your outputs: SNMP polling failures, license changes, server restarts, and critical module failures. Use it to alert in your SIEM when NFO stops processing data or a device stops answering SNMP polls, without reading NFO logs.
Functionality
NFO records operational events on the Logs tab of the Status page and in nfo_audit.log. When this module is enabled, the events listed under Events are also sent to your outputs as syslog or JSON records with nfc_id=20703. Other entries on the Logs tab, such as replies to configuration changes, stay on the Logs tab only.
On the Logs tab and in nfo_audit.log, each event appears as one line in the same key=value format, with its severity and code at the start of the line.
Events are sent even while NFO has stopped processing data because the license is not accepted, so your SIEM can see why data stopped arriving.
Events raised while NFO starts, before the module is running, are sent once it starts, provided they were raised within the last 5 minutes. Events waiting to be sent when the module's configuration is changed or reloaded are lost; this covers at most one Data Collection Interval.
To send events, enable NFO Events (10703) under Modules > Utilities.
Repeated Events
The same event from the same source is sent at most once per 60 seconds. Identical events raised within that time are counted, and the next record sent for that event carries the count in its repeats field.
Two events are the same when their service, event, and identifying fields match. For set_failed, the identifying fields are mgmt_ip, set_name, and request_type.
processing_stopped, processing_resumed, and startup_complete are never combined; each one is sent as it happens.
Parameters
| Parameter Name | Description | Default |
|---|---|---|
| Data Collection Interval, sec | How often collected events are sent. Range: 1 to 60 | 1 sec |
Syslog/JSON Message Fields
Every record carries these fields, with the fields of its event between event and description:
| Field Name | Description | Type | Example / Notes |
|---|---|---|---|
| nfc_id | Message type identifier | string | nfc_id=20703 |
| severity | Event severity | string | emergency, alert, critical, error, warning, notice, informational, or debug |
| code | Numeric event code | number | For SNMP events, the SNMP result code; for module failures, the error code. e.g. -1 |
| service | Area of NFO that raised the event | string | SNMP, LICENSE, SERVER, or CONFIG |
| event | Event name | string | See Events. e.g. set_failed |
| description | Short human-readable description | string | e.g. Unresponsive device |
| repeats | Number of identical events combined into this record | number | Present only when events were combined; always the last field. See Repeated Events |
Events
| Service | Event | Severity | Sent when | Event fields |
|---|---|---|---|---|
| SNMP | set_failed | notice | An OID set on a device stopped answering and its polling is suspended | mgmt_ip, exp_ip, snmp_port, set_name, request_type, bulk, suppressed_until |
| LICENSE | accepted | notice | A license is accepted | product, customer, issued, expires, options, license_path |
| LICENSE | refused | warning | A license is refused | reason, license_dir |
| LICENSE | check_failed | warning | The license cannot be checked | reason |
| LICENSE | processing_stopped | warning | NFO stopped processing data because the license is not accepted | |
| LICENSE | processing_resumed | notice | NFO resumed processing data | |
| SERVER | startup_complete | notice | NFO finished starting. Marks every NFO restart | |
| SERVER | events_dropped | warning | Events were lost because they could not be queued for sending | queue_full, no_memory |
| CONFIG | module_deregister_failed | alert | A module could not be deregistered. This is a critical failure | module, error |
SNMP Polling Failures
A set_failed event is sent when an OID set on a device in the SNMP device lists fails to answer and its polling is suspended for the period set by NFO_SNMP_INACTIVE_POLL_TIMEOUT (default 3600 seconds, range 60 to 86400). While the set keeps failing, one event is sent per suspension period, so a device that stays down produces one event per OID set per hour by default.
Any change to the SNMP device lists ends all current suspensions. Suspended sets are then polled again, so set_failed can repeat before the suspension period is over. For how suspension works, see Suspending SNMP Polling from Inactive Devices.
| Field Name | Description | Type | Example / Notes |
|---|---|---|---|
| mgmt_ip | SNMP management IP address of the device | IPv4 address or IPv6 address | e.g. 172.31.19.66 |
| exp_ip | Exporter IP address of the device | IPv4 address or IPv6 address | e.g. 172.31.19.66 |
| snmp_port | SNMP port | number | e.g. 161 |
| set_name | Name of the OID set that failed | string | default for interface information requested for flow enrichment. e.g. host_mem |
| request_type | Kind of SNMP request | string | default, arbitrary, or table |
| bulk | Whether the table was read with GetBulk | number | 1 when GetBulk was used |
| suppressed_until | Time polling of the set resumes, in UTC | string | e.g. 2026-08-11T11:39:04Z |
No event is sent when a set answers again. Polling resumes after suppressed_until, and the device's data reappears once it answers.
Failures for devices that are not in the SNMP device lists are not sent; they appear on the Logs tab only.
Example:
nfc_id=20703 severity=notice code=-1 service=SNMP event=set_failed mgmt_ip=172.31.19.66 exp_ip=172.31.19.66 snmp_port=161 set_name="host_mem" request_type=table bulk=1 suppressed_until=2026-08-11T11:39:04Z description="Unresponsive device"
License Events
processing_stopped is the most important event to alert on. When the license is not accepted, NFO stops processing data, and your outputs stop receiving it. This event explains the gap, and processing_resumed marks the end of it. Both are sent only when processing actually stops or resumes, not at every license check.
| Field Name | Description | Type | Events |
|---|---|---|---|
| product | Licensed product | string | accepted |
| customer | Customer the license is issued to | string | accepted |
| issued | Date the license was issued | string | accepted |
| expires | Date the license expires | string | accepted |
| options | Licensed options | string | accepted |
| license_path | Path of the accepted license file | string | accepted |
| reason | Why the license was refused or could not be checked | string | refused, check_failed |
| license_dir | Directory NFO searched for a license file | string | refused |
Example:
nfc_id=20703 severity=warning code=406 service=LICENSE event=processing_stopped description="Message processing is stopped"
For license management, see Licensing.
Server Events
startup_complete is sent once each time NFO starts, after it has loaded its configuration and begun receiving data. Use it to tell a restart apart from an interruption in data.
events_dropped means some events were lost before they could be sent. It is sent by the module itself.
| Field Name | Description | Type |
|---|---|---|
| queue_full | Number of events dropped because the event queue was full | number |
| no_memory | Number of events dropped because memory was not available | number |
Module Failures
module_deregister_failed is sent when NFO cannot deregister a module, for example while applying a configuration change. This is a critical failure; contact NetFlow Logic Support if you receive this event.
| Field Name | Description | Type |
|---|---|---|
| module | Module that could not be deregistered | string |
| error | Error code. The same value is in code | number |